Setting up FSI XMP monitor
Livegrade comes with support for the Flanders Scientific FSI XMP monitors that enables you to control the look ofup to 4 SDI channels by using a network connection.
This article is representatively tailored to the Flanders Scientific XMP 310. A list of all the FSI DM and XMP monitors supported can be found in the Knowledge Base article All Supported Devices in Livegrade.
Adding an FSI XMP monitor as a look device#
In order to exchange look information with Livegrade, the FSI XMP monitor needs to
- run on XMP firmware 3.2.10 or later
- have a working network connection with the computer where Livegrade is running on.
- be set to Input Color Mode -> Global from the monitor’s Color-Input menu.
Once the network connection has been established, you can check the IP address of the monitor.
In order to configure the monitor’s IP address:
- Go to the Main Menu -> System -> Current IP
Once you have obtained the device’s IP address, you can add the FSI monitor to any input slot using the slot manager.
Open the slot manager
- by clicking on the Slot Manager symbol in the toolbar or
- via the menu: Livegrade > [Slot Manager…]

In the slot manager, click on the input you want to add the device to.
Within an input click on + Add Device in the Look Devices section and select FSI XMP Monitor to add the monitor to your slot.
After adding the FSI XMP monitor a configuration form will appear.

Add FSI XMP Monitor
Configure and connect FSI XMP monitor#
Host textfieldEnter the device’s IP address
Look Update toggleChoose whether the look should be updated interactively or manually.
- Interactive: Look will be updated several times as second
- Manual Upload: Look in device will be updated when triggering “Upload Look to Device(s)”. This action can be triggered
- via a dedicated button in the main toolbar
- via the main menu (Slots > Upload Look to Device(s))
- via Stream Deck action
- via Tangent actionor manually (via “Upload Look to Device” action, which can be triggered by menu items, toolbar buttons, Stream Deck and Tangent actions)
Finally, click on Connect to add the device to the slot. After that the current look of the corresponding input slot will always be sent to the grading device as long as the input slot is in Live mode.
Change configuration#
In order to change the configuration of the device
- disconnect the device via pressing the Disconnect button
- change the configuration and
- press Connect to connect to the device again
Configure channels#
After connecting to the device, all available channels of the device will be listed.
On first connect, the first channel will be assigned to the current slot.
In the following you will learn how to
- Add a channel to a different slot
- Change the assignment of a channel
- Change the HDR/SDR pipeline of a channel
Assign channel to a different slot#
- Select another slot in the slot list on the left side
- Click on the “+ Add Device” button
- All available channels will be listed at the top of the list
- Select the channel you want to assign
Change the assignment of a channel#
- Disconnect the device via pressing the Disconnect button
- Enable/disable the toggle next to the channel you want to assign
- Press Connect to connect to the device again
Change HDR/SDR pipeline#
If you are on a dual monitoring workflow, you can decide whether your channel should receive the HDR or SDR look.
In order to configure that
- Disconnect the device via pressing the Disconnect button
- Chose the HDR/SDR option within each channel
- Optional: if you want to see the SDR look within an HDR container, enable the SDR display simulation option
- Press Connect to connect to the device again
Store LUT permanently on device#
The action to store the current look of a slot to the channel of the FSI XMP monitor can be triggered via the main menu or automatically triggered when quitting Livegrade.
To manually trigger the action
- Select* Slots > *Permanently store current looks on devices… via the main menu
To automatically trigger the action when quitting Livegrade
- Check Store look in devices when quitting Livegrade in the Devices tab of Livegrade settings
On FSI XMP monitors, LUTs are stored in the monitors LUTs 1, 2, 3, and 4, with each corresponding to channel 1 through 4.